How to Top Up a Worcester Boiler (Without a Key, or With One)

Three ways Worcester boilers get topped up, what to do when the filling key has vanished, and why you shouldn’t force anything with a screwdriver.

Alex Morgan avatar
Founder & editor
Updated 9 min read
Worcester Bosch combi boiler with the filling key pushed into the port on the underside

You can only top up a Worcester boiler without a key if it has a keyless lever or an external filling loop. Many Greenstar combis have a keyless blue lever underneath: pull it down until the gauge passes 1 bar, then let go. If yours has a keyed internal filling link and the key is lost, you can't safely do it with a screwdriver. Order a genuine replacement key or ask an engineer to do it. Worcester's own guidance is to fill to just over 1 bar when cold.

Worcester Bosch have used more than one way of getting mains water into the heating circuit, and that's why the advice online contradicts itself. The right method depends on what's under your boiler. This page sorts out which of the three you have, how to use it, and what to do if the key has gone missing. If you want the general pressure rules for any brand, start with our boiler pressure guide, or browse the wider home heating section.

First, work out which filling method you have

Crouch down and look at the underside of the boiler, and at the pipes just below it.

  • A black port on the right-hand side, plus a key. This is the keyed internal filling link. Worcester's own instructions describe an open black port at the front right and a key that usually lives on a flap underneath the boiler, or came with your paperwork at installation. British Gas's guide to the same job describes the key clipped inside the underside hatch.
  • A blue lever at the bottom. That's the keyless internal link. No key to lose.
  • A braided hose with two taps, outside the boiler. The external filling loop. It sits on the pipework below, one tap on the cold mains side and one on the heating side.
  • None of the above. Some boilers, particularly older ones with a lost or removed link, have no way for you to top up. That one is a job for an engineer, who can fit a proper filling loop.

If you're unsure of your model, how to tell what type of boiler you have will help.

What pressure to aim for

Manuals differ by model. The Greenstar Ri ErP+ user instructions give 1 to 1.5 bar, while the Greenstar 4000 manual gives 0.8 to 1.7 bar, so check yours. Worcester's support page says to stop at "just over one bar" on a keyed link and "over one bar" on a keyless one, and "about one bar" with an external loop. Other sources, including British Gas, quote 1 to 1.5 bar. Both fit together: the boiler is happy anywhere in that band when cold, so aim for a bit over 1 and stop well before 1.5. Check your own manual for the exact range on your model.

Do it with the boiler cold. A hot system reads higher, and you'll end up with too much water in it.

Topping up with the filling key

This is the method most people searching "increase pressure on Worcester boiler" are really asking about.

Hand holding a small filling key near the port underneath a combi boiler
The key lives on a flap or in your paperwork. Take it out again once you have finished.
  1. Switch the heating off and let the boiler cool.
  2. Find the key. Check the flap or hatch on the underside, then the paperwork and manual drawer.
  3. Find the port: a small round hole on the front right underneath, next to a padlock symbol.
  4. Line up the arrow on the key's shaft with the open padlock symbol and push the key up into the port.
  5. Turn the key and watch the gauge. You'll hear water running in.
  6. Stop when the pressure is just over 1 bar. Turn the key back to the open padlock position.
  7. Pull the key out. A small amount of water will drip. That's normal.
  8. Reset the boiler if it showed a low-pressure fault (see how to reset a Worcester boiler).

Take the key out and put it somewhere you'll find it again. One forum poster ended up past the red mark on the gauge because the key was left in. Don't leave it in the port.

Topping up with the keyless blue lever

Newer models are simpler. Worcester describes a blue lever at the bottom of the boiler: pull it down, watch the gauge, and let go once the pressure is over 1 bar. The lever springs back by itself.

Go slowly. It fills faster than you'd think, and bleeding water back out afterwards is more faff than stopping on time.

Topping up with an external filling loop

On boilers with a braided hose under them, the steps are different.

Braided filling loop hose with two taps beneath a boiler
Open the mains tap first, then the heating tap slowly, and watch the gauge.
  1. Check the hose is attached firmly at both ends. If the hose is detachable, connect both ends hand-tight.
  2. Open the tap on the mains side first.
  3. Open the tap on the heating side slowly. You'll hear the water.
  4. Watch the gauge and close both taps at about 1 bar.
  5. Disconnect the hose if it's meant to be removed, and expect a little drip. The Greenstar Ri ErP+ manual says an external loop must be disconnected after filling to comply with water regulations.

Worcester's own page also says to identify the loop by its two valves: one from the cold mains, one connected to the heating system. If you have a loop with one valve only, follow your manual, since the layout varies.

What if the filling key is lost?

This is where people get tempted to do something daft.

Don't push a screwdriver, a bit of wire or a pair of pliers into the filling port. The link has a valve inside it. Forcing it can damage the seal, jam it open or leave it dripping mains water into the system, which then drives the pressure up. It can also affect your warranty. Worcester will only warrant boilers fitted with their own filling loop or an approved one, according to one DIYnot poster, so improvised fixes are a poor idea.

Your sensible options, in order:

  1. Look properly. Underside flap, installer's paperwork, the boiler cupboard shelf, the junk drawer. Keys are small and get moved.
  2. Buy a genuine replacement key. Worcester Bosch parts suppliers and some plumbers' merchants stock them. Quote your boiler model and serial number so you get the right one. I haven't found a reliable official price, so ring around rather than trusting a number from me.
  3. Ask a Gas Safe engineer to top it up. For a one-off, it's a quick job. Ask them to fit an external filling loop at the same time if you'd rather never deal with a key again.

Can you top up a keyed integral model safely without the key? No. The key is the only tool designed to work the valve, so on those boilers the answer is a replacement key or an engineer. The "without a key" route only exists for boilers that were built without one.

Never remove the boiler casing to try to reach the filling link from inside. That's Gas Safe territory. The topping-up controls are all on the outside, underneath the boiler.

Dial gauge or digital display

Some Worcester boilers show pressure on a round dial with a green zone. Others show a digital reading on the screen. On some models you need to press a button to bring it up. Digital readings sometimes show in tenths, so 1.0 and 1.5 are easy to read, but check your manual for how to wake the display.

On a dial, watch the needle, not the green zone alone. Green zones are wide, and just inside the green isn't always where you want to be when cold.

Pressure too high after topping up

It happens a lot. You overshoot to 2 bar with the heating cold.

  1. Turn the heating off and let the radiators go cold.
  2. Check the filling link is closed. On the key model, the key should be out and the port closed. On a loop, both taps shut.
  3. Bleed a radiator, ideally the one furthest from the boiler. Hold a cloth under the valve and open it with a radiator key. Air hisses out first, then water.
  4. Close the valve when the gauge drops to about 1 to 1.5 bar.

If the pressure keeps creeping up on its own, the filling link may be passing water. Our boiler pressure guide covers the expansion vessel and relief valve causes.

If it keeps dropping

One top-up a year isn't unusual. Topping up every week or two means water is going somewhere: a weeping radiator valve, a joint, the pressure relief pipe outside, or an expansion vessel that has lost its charge. Work through the checks in combi boiler losing pressure, and look at boiler leaking water if you can see drips under the boiler.

Keep topping up a leaking system and you're adding fresh water and oxygen each time, which feeds corrosion and sludge. It's better to fix the leak.

When to call an engineer

  • You can't find a way of topping up, or the filling link doesn't match any of the above.
  • The pressure drops again within days.
  • The pressure rises to 3 bar and the relief pipe drips.
  • There's a fault code that doesn't clear after topping up and one reset.
  • You smell gas. Call the National Gas Emergency Service on 0800 111 999.

FAQs

How do I increase the pressure on a Worcester boiler without a key?

Check for a blue lever underneath or an external braided filling loop. Either lets you top up without a key. If you have a keyed internal link and the key is lost, get a genuine replacement or have an engineer do it.

Where is the filling key on a Worcester boiler?

Usually on a flap or hatch on the underside of the boiler, or it was handed over with the manual at installation. Check both before buying another.

Can I use a screwdriver instead of the Worcester filling key?

No. You risk damaging the valve and the seal, and it could leave the link leaking. A replacement key is a cheap part, so it isn't worth the risk.

What pressure should a Worcester boiler be when cold?

Worcester's guidance is to fill to just over 1 bar, and 1 to 1.5 bar is the common range quoted for combis. Your manual gives the exact figure for your model.

Why does my Worcester boiler lose pressure?

Usually a small leak, a bled radiator, a relief valve discharging, or an expansion vessel issue. If you top up more than every few months, find out why.

The gauge doesn't move when I use the loop. What now?

Check you've found the real fill point, as the loop can be elsewhere, for example near the cylinder on a system boiler. Check both taps are fully open and the hose is tight. If water runs but the gauge stays put, the gauge or sensor may be at fault, so ask an engineer.

Do I need an engineer to top up my Worcester boiler?

No. Worcester's own support page says repressurising can be done without a heating engineer, as long as you use the filling link provided and never open the casing.

  • Keyless lever or external loop: you can top up without a key.
  • Keyed internal link and a lost key: buy the genuine key or call an engineer, never force it.
  • Fill cold, to just over 1 bar, and take the key out afterwards.
  • Too high? Bleed a radiator. Dropping again? Find the leak.